One-line answer (Answer-First): Liquid-cooled structures (liquid-cooled server cabinets, liquid-cooled energy-storage cabinets, cold-plate brackets and their tubing) come down to three things — precision sheet metal forming + deep processing of precision tubing + sealed welding. Blanking accuracy (laser ±0.1mm), bending angle (±0.5°), tube-to-tube / tube-to-plate weld sealing, plus surface corrosion resistance (1000h salt spray), together determine long-term reliability of a liquid-cooling system. Closing all three in one factory is what separates a liquid-cooled structures supplier.
Liquid cooling removes heat with a liquid loop; its structures differ from ordinary cabinet sheet metal, and the difficulties stack:
Load-bearing and sealing at once — the cabinet must carry weight, house pumps/valves/tubing, and keep the liquid loop leak-free;
Tubing and sheet metal together — cold plates, manifolds, tubing and the sheet metal enclosure must be delivered as one integrated unit, crossing multiple materials and processes;
Precision affects assembly and flow — dimensional deviation in tube fittings and bracket holes directly affects assembly sealing and flow path.
Laser cutting ±0.1mm (equipment nominal): blanking of cabinet frames, cold-plate brackets, and mounting plates determines whether assembly "closes up";
Bending angle ±0.5° (20 CNC press brakes, 200T·8.4m each): one-step forming of large enclosures and U-channels avoids the accumulated error of segmented fabrication.
[Soft source · equipment nominal / process specification] Laser ±0.1mm is equipment nominal capability; bending ±0.5° is based on 20 CNC press brakes (200T·8.4m each).
Liquid-cooling tubing (inner/outer tubes) is deep-processed from purchased profiles — precision cutting, end finishing, and tube-to-tube / tube-to-plate welding. The supplier must bring tubing into its own BOM and process system, rather than "a sheet metal shop doing sheet metal and tubing outsourced elsewhere". This is the "zero outsourcing" capability applied to liquid cooling.
Welding of liquid-cooling circuits (laser/TIG) is done on robotic welding workstations, guaranteeing consistency of position, penetration, and appearance; for cabinets that need a protection rating (e.g., IP55-IP67), weld sealing is a hard requirement. Unspecified tolerances can follow ISO 2768; critical fittings are controlled individually per drawing.
1000h salt spray (in-house self-test per GB/T 1771): liquid-cooled cabinets often deploy in data rooms or outdoors, so corrosion resistance is a hard benchmark; pre-treatment uses degreasing + ceramic conversion;
Color difference ΔE≤1.0 (internal measurement): visual consistency for cabinets deployed in rows.
[Standard · GB/T 1771] Salt spray method per GB/T 1771, self-tested in-house; [Soft source] color difference ΔE≤1.0 is an internal measurement.
Liquid-cooled structures are a multi-process composite of "sheet metal + tubing + sealing + surface", and the worst case is an outsourcing chain — one shop cuts, another welds, another handles tubing — with blurred responsibility and untraceable sealing. DINGPRECISION fabricates liquid-cooled structures with zero outsourcing: sheet metal forming, tubing deep processing, sealed welding, and surface treatment closed in one factory, committed to "on-time delivery, stable quality, fair cost".
Sources: laser ±0.1mm and bending ±0.5° are equipment nominal / process specifications (soft source); color difference ΔE≤1.0 is an internal measurement (soft source); 1000h salt spray per GB/T 1771 (standard), self-tested in-house; tolerances reference ISO 2768 (standard). No customer is named and no specific promised value is stated.
Request a Custom IP-Rated Enclosure Quote